  data modul ag - www.data-modul.com specification m201un02 v.3 version september 2005 note: this specification is subject to change without prior notice www.speclcd.com www.speclcd.com www..net
. product spec ifications 20.1 ? uxga color tft-lcd module model name: m201un02 v.3 ( ? ) preliminary specifications ( ) final specifications note: this specification is subject to change without notice. data modul ag - www.data-modul.com 2 www.speclcd.com www.speclcd.com www..net
i contents ii record of revision 1.0 handling precautions 2.0 general description 2.1 display characteristics 2.2 functional block diagram 2.3 optical characteristics 2.4 pixel format image 3.0 electrical characteristics 3.1 absolute maximum ratings 3.2 connectors 3.3 signal pin 3.4 signal description 3.5 signal electrical characteristics 3.6 interface timing 3.6.1 timing characteristics 3.6.2 timing definition 3.7 power consumption 3.8 power on/off sequence 4.0 backlight characteristics 4.1 signal for lamp connector 4.2 parameter guide line for ccfl inverter 5.0 vibration, shock and drop 5.1 vibration and shock 5.2 drop test 6.0 environment 6.1 temperature and humidity 6.1.1 operating conditions 6.1.2 shipping conditions 6.2 atmospheric pressure 6.3 thermal shock 7.0 reliability 7.1 failure criteria 7.2 failure rate 7.2.1 usage 7.2.2 components de-rating 7.3 ccfl life 7.4 on/off cycle 8.0 safety 8.1 sharp edge requirement 8.2 material 8.2.1 toxicity 8.2.2 flammability 8.3 capacitors 8.4 hazardous voltage 9.0 other requirements 9.1 smoke free design 9.2 national test lab requirement 10.0 mechanical characteristics data modul ag - www.data-modul.com 3 www.speclcd.com www.speclcd.com www..net
. ii record of revision version and date page old description new description remark 0.1 2003/12/01 all first edition for customer all 1.0 handling precautions 1) since front polarizer is easily damaged, pay attention not to scratch it. 2) be sure to turn off power supply when inserting or disconnecting from input connector. 3) wipe off water drop immediately. long contact with water may cause discoloration or spots. 4) when the panel surface is soiled, wipe it with absorbent cotton or other soft cloth. 5) since the panel is made of glass, it may break or crack if dropped or bumped on hard surface. 6) since cmos lsi is used in this module, take care of static electricity and insure human earth when handling. 7) do not open nor modify the module assembly. 8) do not press the reflector sheet at the back of the module to any directions. 9) at the insertion or removal of the signal interface connector, be sure not to rotate nor tilt the interface connector of the tft-lcd module. 10) after installation of the tft-lcd module into an enclosure (lcd monitor housing, for example), do not twist nor bend the tft -lcd module even momentary. at designing the enclosure, it should be taken into consideration that no bending/twisting forces are applied to the tft -lcd module from outside. otherwise the tft -lcd module may be damaged. data modul ag - www.data-modul.com 4 www.speclcd.com www.speclcd.com www..net
2.0 general description this specification applies to the 20.1 inch color tft-lcd module m201un02 v.3. the display supports the uxga (1600(h) x 1200(v)) screen format and 16.7m colors (rgb 8-bits data). all input signals are 2 channel lvds interface compatible. this module does not contain an inverter card for backlight. 2.1 displa y characteristics the following items are characteristics summ ary on the table under 25  condition: items unit specifications screen diagonal [mm] 510(20.1") active area [mm] 408.0 (h) x 306.0 (v) pixels h x v 1600(x3) x 1200 pixel pitch [mm] 0.255 (per one triad) x 0.255 pixel arrangement r.g.b. vertical stripe display mode normally black white luminance [cd/m 2 ] 250 cd/m 2 (typ) contrast ratio 700 : 1 (typ) optical response time ( gray to gray) [msec] 16 (typ) nominal input voltage vdd [volt] +5.0 v power consumption (vdd line + ccfl line) [watt] 45w(typ.) (w/o inverter, all white pattern) weight [grams] 3000 (typ) physical size [mm] 432(w) x 331.4(h) x 23.1(d) electrical interface even/odd r/g/b data, 3 sync signal, clock support color 16.7m colors (rgb 8-bit data ) temperature range operating storage (shipping) [ o c] [ o c] 0 to +50 -20 to +60 data modul ag - www.data-modul.com 5 www.speclcd.com www.speclcd.com www..net
2.2 functional block diagram the following diagram shows the funct ional block of the 20.1 inches color tf t-lcd module: lvds + 5v inverter jae fi-xb30sl-hf10 jst bhsr-02vs-1 (2 pin) mating type: jae fi-x30s-h mating type: sm02b-bhss-1 jst bhr-05vs-2 (5 pin) mating type: sm04b-bhs-1 connector dc/dc converter lvds receiver timing controller gamma correction tft-lcd 1600*(3)*1200 pixels x - driver ic y - driver ic g1 g1200 d1 d4800 inverter dc power 6 ccfl i/f + x-pcb au asic over driving data modul ag - www.data-modul.com 6 www.speclcd.com www.speclcd.com www..net
2.3 optical characteristics the optical characteristics are measured under stable conditions at 25  (room temperature): item unit conditions min. typ. max. [degree] [degree] horizontal (right) cr = 10 (left) 75 85 85 - - viewing angle [degree] [degree] vertical (up) cr = 10 (down) 75 85 85 - - contrast ratio normal direction 400 700 [msec] raising time - 15 25 [msec] falling time - 10 15 response time (note 1 & 4) [msec] raising + falling - 25 40 [msec] gray to gray - 16 red x 0.618 0.648 0.678 red y 0.309 0.339 0.369 green x 0.259 0.289 0.319 green y 0.568 0.598 0.628 blue x 0.113 0.143 0.173 color / chromaticity coordinates (cie) blue y 0.048 0.078 0.108 white x 0.283 0.313 0.343 color coordinates (cie) white white y 0.299 0.329 0.359 white luminance at ccfl 6.0ma (central point) [cd/m 2 ] 200 250 - luminance uniformity (note 2) [%] 75 80 - crosstalk (in 60hz) (note 3) [%] 1.5 equipment pattern generator, power supply, digital voltmeter, luminance meter (pr 880, bm-5a , bm- 7 , & ezcontrast* ) aperture 1  with 100cm vd or 2  with 50cm viewing distance test point center (iso point 22) environment < 1 lux ? * ? ez contrast is different measurement tool with very close viewing distance. lcd module pr-880 / bm5a / bm7 module driving equipment measuring distance data modul ag - www.data-modul.com 7 www.speclcd.com www.speclcd.com www..net
note 1: definition of response time: the output signals of photodetector are measured when the input signals are changed from ? black ? to ? white ? (rising time), and from ? white ? to ? black ? (falling time), respectively. the response time is interval between the 10% and 90% of amplitudes. refer to figure as below. note 2: brightness uniformity of these 9 points is defined as below: minimum luminance in 9 points (1-9) uniformity = ??????????????????? 50 % 90 % 90 % 50 % 10 % 10 % optical res p onse 100% 90% 10% 0% t f t r white black white data modul ag - www.data-modul.com 8 www.speclcd.com www.speclcd.com www..net
maximum luminance in 9 points (1-9) note 3: crosstalk is defined as below : unit: percentage of dimension of display area l l a -l a? l / l a x 100%= 1.5% max., l a and l b are brightness at location a and b l l b -l b? l / l b x 100%= 1.5% max., l a? and l b? are brightness at location a ? and b ? note 4: over-drive and response time: algorithm: 16 b level - a level ms t ms t f r 16&16 ? b ? 184 gray level 184 gray level 0 gray level 0% 10% 90% 100% time time optical response driving signal a b tr tf data modul ag - www.data-modul.com 9 www.speclcd.com www.speclcd.com www..net
2.4 pixel format image following figure shows the relationship of the input signals and lcd pixel format. r g b r g b r g b r g b r g b r g b r g b r g b 1 2 1599 1600 1st line 1200 th line data modul ag - www.data-modul.com 10 www.speclcd.com www.speclcd.com www..net
3.0 electrical characteristics 3.1 absolute maximum ratings absolute maximum ratings of the module is as following: item symbol min max unit conditions logic/lcd drive voltage vin -0.3 +5.5 [volt] select lvds data order sellvds nc nc [volt] ccfl inrush current icfll - 40 [ma] note 1 ccfl current icfl - 7.5 [ma] rms operating temperature top 0 +50 [ o c] note 2 operating humidity hop 8 95 [%rh] note 2 storage temperature tst -20 +60 [ o c] note 2 storage humidity hst 8 95 [%rh] note 2 note 1 : duration=50 msec. note 2 : maximum wet-bulb should be 39  and no condensation. t=65 ,h=29% relative humidity % tem p erature o c -20 06 0 50 95 5 100 0 operation range storage range storage 80 60 40 20 twb=39  t=40 ,h=95% t=60 ,h=39% t=50 ,h=55% data modul ag - www.data-modul.com 11 www.speclcd.com www.speclcd.com www..net
3.2 connectors physical interface is described as for the connector on module. these connectors are capable of accommodating the following signals and will be following components. connector name / designation interface connector / interface card manufacturer jae or compatible type part number fi-xb30sl-hf10 mating housing part number fi-x30s-h connector name / designation lamp connector / backlight lamp manufacturer jst type part number bhsr-02vs-1 (2 pin), bhr-05vs-2 (5 pin) mating type part number sm02b-bhss-1(2 pin), sm04b-bhs-1 (5 pin) 3.3 signal pin pin# signal name pin# signal name 1 rxo0- 2 rxo0+ 3 rxo1- 4 rxo1+ 5 rxo2- 6 rxo2+ 7 gnd 8 rxoc- 9 rxoc+ 10 rxo3- 11 rxo3+ 12 rxe0- 13 rxe0+ 14 gnd 15 rxe1- 16 rxe1+ 17 gnd 18 rxe2- 19 rxe2+ 20 rxec- 21 rxec+ 22 rxe3- 23 rxe3+ 24 gnd 25 nc 26 nc 27 nc 28 power 29 power 30 power data modul ag - www.data-modul.com 12 www.speclcd.com www.speclcd.com www..net
3.4 signal description the module using a pair of lvds receiver sn75lvds82(texas instruments) or compatible. lvds is a differential signal technology for lcd interface and high speed data transfer device. transmitter shall be sn75lvds83(negative edge sampling) or compatible . the first lvds port(rxoxxx) transmits odd pixels while the second lvds port(rxexxx) transmits even pixels. pin # signal name description 1 rxo0- negative lvds differential data input (odd data) 2 rxo0+ positive lvds differential data input (odd data) 3 rxo1- negative lvds differential data input (odd data) 4 rxo1+ positive lvds differential data input (odd data) 5 rxo2- negative lvds differential data input (odd data, h-sync,v-sync,dsptmg) 6 rxo2+ positive lvds differential data input (odd data, h-sync,v-sync,dsptmg) 7 gnd power ground 8 rxoc- negative lvds differential clock input (odd clock) 9 rxoc+ positive lvds differential clock input (odd clock) 10 rxo3- negative lvds differential data input (odd data) 11 rxo3+ positive lvds differential data input (odd data) 12 rxe0- negative lvds differential data input (even clock) 13 rxe0+ positive lvds differential data input (even data) 14 gnd power ground 15 rxe1- positive lvds differential data input (even data) 16 rxe1+ negative lvds differential data input (even data) 17 gnd power ground 18 rxe2- negative lvds differential data input (even data) 19 rxe2+ positive lvds differential data input (even data) 20 rxec- negative lvds differential clock input (even clock) 21 rxec+ positive lvds differential clock input (even clock) 22 rxe3- negative lvds differential data input (even data) 23 rxe3+ positive lvds differential data input (even data) 24 gnd power ground 25 nc - 26 nc - 27 nc - 28 power power 29 power power 30 power power note: input signals of odd and even clock shall be the same timing. lvds data name description dsp display timing: when the signal is high, the pixel data shall be valid to be displayed v-s vertical sync: both positive and negative polarity are acceptable h-s horizontal sync: both positive and negative polarity are acceptable data modul ag - www.data-modul.com 13 www.speclcd.com www.speclcd.com www..net
ti lvds x ? mitter sn75lvds83 module lvds signal (interface connector pin7) signal name low(open) d0 red0 d1 red1 d2 red2 d3 red3 d4 red4 d5 red7 d6 red5 d7 green0 d8 green1 d9 green2 d10 green6 d11 green7 d12 green3 d13 green4 d14 green5 d15 blue0 d16 blue6 d17 blue7 d18 blue1 d19 blue2 d20 blue3 d21 blue4 d22 blue5 d23 na d24 h sync d25 v sync d26 display timing d27 red6 data modul ag - www.data-modul.com 14 www.speclcd.com www.speclcd.com www..net
note: r/g/b data 7:msb, r/g/b data 0:lsb o = ? first pixel data ? e = ? second pixel data ? rxoin0 rxo n1 rx o in2 rx o in 3 rxoclki rxeclki rxein2 rxein0 rxein3 rxein1 g0 r5 r4 r3 r2 r1 r0 b1 b0 g5 g4 g3 g2 g1 b2 b3 b4 b5 hs vs de rsv b7 b6 g7 g6 r7 r6 g0 r5 r4 r3 r2 r1 r0 b1 b0 g5 g4 g3 g2 g1 b2 b3 b4 b5 rsv b7 b6 g7 g6 r7 r6 data modul ag - www.data-modul.com 15 www.speclcd.com www.speclcd.com www..net
3.5 signal electrical characteristics input signals shall be low or hi-z state when vin is off it is recommended to refer the specifications of sn75lvds82dgg (texas instruments) in detail. each signal characteristics are as follows; parameter condition min max unit vth differential inputhigh voltage(vcm=+1.2v) 100 [mv] vtl differential input low voltage(vcm=+1.2v) -100 [mv] note: the value of vcm from lvds transmitter should follow the following guide. parameter min typ. max unit vcm +1.0 +1.2 +1.35 [v] 3.6 interface timings basically, interface timings described here is not actual input timing of lcd module but output timing of sn75lvds82dgg (texas instruments) or equivalent. 3.6.1 timing characteristics (de mode only) signal item symbol min typ max unit period tv 1211 - 2048 th active tdisp(v) 1200 1200 1200 th vertical section blanking tbp(v)+tfp(v)+pwvs 11 - 848 th period th 860 - 1500 tclk active tdisp(h) 800 800 800 tclk horizontal section blanking tbp(h)+tfp(h)+pwhs 60 - 700 tclk period tclk 12 - - ns clock frequency freq - - 83 mhz data modul ag - www.data-modul.com 16 www.speclcd.com www.speclcd.com www..net
3.6.2 timing definition note :1600x1200 at 60 hz (vesa standard) hsync pixel n 1 m invalid d ata tdisp(v) 10 de de invalid d ata rgb data th 2 rgb data (even) 39 m - 1 invalid d ata 1 n hsync m-2 invalid d ata 11 65 m-3 vsync invalid d ata clk m-5 invalid d ata m-4 7 2 tbp(h) pixel pixel pixel pixel pixel rgb data (odd) 12 tbp(v) tclk pixel pixel pixel pixel pixel pixel pixel pixel pixel pixel pixel pixel 8 4 3 4 tv tdisp(h) line line line line line line tfp(v) tfp(h) pwvs pwhs data modul ag - www.data-modul.com 17 www.speclcd.com www.speclcd.com www..net
3.7 power consumption input power specifications are as follows; symbol parameter min typ max units condition vdd logic/lcd drive voltage 4.5 5 5.5 [volt] idd vdd current 1300 [ma] iidd inrush vdd current 7 [a] t < 80us pdd vdd power 6.5 8 [watt] vin=5v, all white pattern vddrp allowable logic/lcd drive ripple voltage 100 [mv] p-p vddns allowable logic/lcd drive ripple noise 100 [mv] p-p data modul ag - www.data-modul.com 18 www.speclcd.com www.speclcd.com www..net
3.8 power on/off sequence vin power and lamp on/off sequence is as follows. interface signals are also shown in the chart. signals from any system shall be hi-z state or low level when vin is off. values symbol min typ max unit t1 0.5 - 10 [ms] t2 0.5 40 50 [ms] t3 200 - - [ms] t4 200 - - [ms] t5 0.5 16 50 [ms] t6 0.5 - 10 [ms] t7 1000 - - [ms] 10% 90% 90% 10% t1 t2 t5 t6 t7 t3 t4 0v lamp signal vin 10% 0v 0v 10% 90% 90% 10% t1 t2 t5 t6 t7 t3 t4 0v lamp signal vin 10% 0v 0v 10% 90% 90% 10% t1 t2 t5 t6 t7 t3 t4 0v lamp signal vin 10% 0v 0v data modul ag - www.data-modul.com 19 www.speclcd.com www.speclcd.com www..net
4.0 backlight characteristics 4.1 signal for lamp connector pin # signal name 1 lamp high voltage 2 lamp high voltage 3 ground (black) 4 ground (white) pin # signal name 1 lamp high voltage 2 ground (white) 4.2 parameter guide line for cfl inverter symbol parameter min typ max units condition iscfl ccfl standard current 5.5 6.0 6.5 [ma] rms (ta=25 o c) ircfl ccfl operation range 4.0 6.0 7.5 [ma] rms (ta=25 o c) fcfl ccfl frequency 35 50 80 [khz] (ta=25 o c) note 1 vicfl (0 o c) ccfl ignition voltage note 4 1700 [volt] rms (ta=0 o c) note 2 vicfl (25 o c) ccfl ignition voltage note 4 1200 [volt] rms (ta=25 o c) note 2 vcfl ccfl discharge voltage (reference) @ 6m a 760 825 [volt] rms (ta=25 o c) note 3 pcfl ccfl power consumption @6ma 27 29.7 [watt] (ta=25 o c) note 3 note 1: ccfl frequency should be carefully determined to avoid interference between inverter and tft lcd note 2: ccfl inverter should be able to give out a power that has a generating capacity of over 1700 voltage. lamp units need 1700 voltage minimum for ignition note 3: calculator value for reference (icfl vcfl=pcfl) note 4: (measure for both end of lamp wire) data modul ag - www.data-modul.com 20 www.speclcd.com www.speclcd.com www..net
5.0 vibration, shock, and drop 5.1 vibration & shock frequency: 10 - 200hz sweep: 30 minutes each axis (x, y, z) acceleration: 1.5g(10~200hz p- p) test method: acceleration (g) 1.5 frequency (hz) 10~200~10 active time(min) 30 5.2 shock test spec: acceleration (g) ? a 50 active time -b 20 wave form half-sin times 1 direction:  x ,  y,  z 5.3 drop test package test: the drop height is 60 cm. 6.0 environment the display module will meet the provision of this specification during operating condition or after storage or shipment condition specified below. operation at 10% beyond the specified range will not cause physical damage to the unit. 6.1 temperature and humidity 6.1.1 operating conditions the display module operates error free, when operated under the following conditions; temperature 0 0 c to 50 0 c relative humidity 8% to 95% wet bulb temperature 39.0 0 c data modul ag - www.data-modul.com 21 www.speclcd.com www.speclcd.com www..net
6.1.2 shipping conditions the display module operates error free, after the following conditions; temperature -20 0 c to 60 0 c relative humidity 8% to 95% wet bulb temperature 39.0 0 c 6.2 atmospheric pressure the display assembly is capable of being operated without affecting its operations over the pressure range as following specified; pressure note maximum pressure 1040hpa 0m = sea level minimum pressure 674hpa 3048m = 10.000 feet note : non-operation attitude limit of this display module = 30,000 feet. = 9145 m. 6.3 thermal shock the display module will not sustain damage after being subjected to 100 cycles of rapid temperature change. a cycle of rapid temperature change consists of varying the temperature from -20 0 c to 60 0 c, and back again. thermal shock cycle -20 0 c for 30min 60 0 c for 30min power is not applied during the test. after temperature cycling, the unit is placed in normal room ambient for at least 4 hours before powering on. 7.0 reliability this display module and the packaging of that will comply following standards. 7.1 failure criteria the display assembly will be considered as failing unit when it no longer meets any of the requirements stated in this specification. only as for maximum white luminance, following criteria is applicable. note : maximum white luminance shall be 125 cd/m 2 or more. 7.2 failure rate the average failure rate of the display module (from first power-on cycle till 1,000 hours later) will not exceed 1.0%. the average failure rate of the display module from 1,000 hours until 16,000 hours will not exceed 0.7% per 1000 hours. data modul ag - www.data-modul.com 22 www.speclcd.com www.speclcd.com www..net
7.2.1 usage the assumed usage for the above criteria is: 220 power-on hours per month 500 power on/off cycles per month maximum brightness setting operation to be within office environment (25 0 c typical) 7.2.2 component de-rating all the components used in this device will be checked the load condition to meet the failure rate criteria. 7.3 ccfl life the assumed ccfl life will be longer than 30,000 hours, typical value is 50,000 hours under stable condition at 25 5 o c; standard current at 6.0 0.5ma. definition of life: brightness becomes 50% or less than the minimum luminance value of ccfl. 7.4 on/off cycle the display module will be capable of being operated over the following on/off cycles. on/off value cycles +vin and ccfl power 30,000 10 seconds on / 10 seconds off 8.0 safety 8.1 sharp edge requirements there will be no sharp edges or comers on the display assembly that could cause injury. 8.2 materials 8.2.1 toxicity there will be no carcinogenic materials used anywhere in the display module. if toxic materials are used, they will be reviewed and approved by the responsible auo toxicologist. 8.2.2 flammability all components including electrical components that do not meet the flammability grade ul94-v1 in the module will complete the flammability rating exception approval process. the printed circuit board will be made from material rated 94-v1 or better. the actual ul flammability rating will be printed on the printed circuit board. 8.3 capacitors if any polarized capacitors are used in the display assembly, provisions will be made to keep them from being inserted backwards. data modul ag - www.data-modul.com 23 www.speclcd.com www.speclcd.com www..net
. 9.0 other requirements 9.1 national test lab requirement the display module will satisfy all requirements for compliance to ul 1950, first edition u.s.a. information technology equipment csa c22.2 no.950-m89 canada, information technology equipment eec 950 international, information technology equipment en 60 950 international, information processing equipment (european norm for iec950) 9.2 label 9.2.1 product label to be defined 10.0 mechanical characteristics data modul ag - www.data-modul.com 24 www.speclcd.com www.speclcd.com www..net
www.speclcd.com www.speclcd.com www..net
www.speclcd.com www.speclcd.com www..net
d a t a m o d u l a g landsberger-str. 322 d-80687 munich tel.: +49-89-56017-0 fax: +49-89-56017-119 d a t a m o d u l s a l e s o f f i c e d s s e l d o r f fritz-vomfelde-str. 8 d-40547 dsseldorf tel.: +49-211-52709-0 fax: +49-211-52709-19 d a t a m o d u l s a l e s o f f i c e s t u t t g a r t friedrich-list-str. 42 d-70771 leinfelden-echterdingen tel.: +49-711-782385-0 fax: +49-711-782385-29 d a t a m o d u l i n c . / u s a 1767-46 veterans memorial highway islandia ny 11749 usa tel.: +1-631-951-0800 fax: +1-631-951-2121 www.data-modul.com display@data-modul.com d a t a m o d u l l t d . / u k 3 brindley place birmingham b12jb uk tel.: +44 121 698 8641 fax: +44 121 698 8623 www.speclcd.com www.speclcd.com www..net


▲Up To Search▲   

 
Price & Availability of M201UN02-V3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X